When you click on the
DETAILS ANALYSIS button on the main menu, you are directed to the page,
which presents
a detailed view on all signals that you have recorded for one
particular
patient.
The available menu is as follows:
|
Channel
|
All channels
|
Spectrum
|
Histogram
|
Scatterogram
|
3D time distribution
|
You enter automatically the Channels page:
1. CHANNEL

The dropdown box at the bottom of the screen
contains two options – Channel 1 for ECG signal, and Channel 2 for
plethismographic signal.
Using the left and right arrow at the bottom left
corner - by changing the position of the cursor you can see the
relevant
numerical value. You can also zoom in and zoom out the x- and y-axes.
Using the MIRROR, SMOOTH, and CUT AREA buttons at
the bottom of the screen you can change the view of the graph.
The PRINT button allows you to print the graph.
2. ALL CHANNELS
The ALL CHANNELS page allows you to monitor
simultaneously all channels through which signals were recorded.

3. SPECTRUM
When you press the SPECTRUM button from the
DETAILS
main page, you are directed toward the page where you can view in
details the
spectrum of a recorded signal of your choice.
The upper curve presents the whole ECG signal, and
all recorded cardiointervals are displayed as a tachogram. The lower
curve displays
the spectral power. Using the mouse or the arrows on the upper graph
you can
select an extract of the tachogram, and it will be presented on the
lower graph
as a spectral curve.
The upper left corner contains a dropdown menu,
which allows you to choose between all channels through which an ECG
signal has
been recorded.
The other dropdown menu contains different options
to display the graphical representation of the spectral power in the
different
spectral frequency areas.
The REVERT, SMOOTH, and CUT AREA buttons in the
bottom of the screen allow you to customize your view of the spectral
curve.
The PRINT button allows you to print the results.
Using the Cursor X menu
in the bottom left corner of the screen, you can change the position of
the
cursor on the lower graph by the left and right arrow in order to view
the
respective positions and the relevant numerical values.
Using the ZOOM X and ZOOM Y menus in the bottom
left corner of the screen you can zoom in and zoom out the x- and
y-axes by the
+/- arrow, and to review the respective numerical values.

4. HISTOGRAM
When you press the HISTOGRAM button from the
DETAILS main page, you are directed toward the page where you can
review in details
the cardiointervals frequency distribution in a specific way.
By the supporting buttons it is possible to move
the marker along the histogram, to select areas for more detailed
examining, as
well as to delete areas with great number of registered artefacts.
You can change the position of the cursor and view
its position using the CURSOR X menu in the upper right corner of the
screen.
You can also zoom in and zoom out the x- and
y-axes
using the left and right arrow below the CURSOR X menu.

Below the ZOOM X and
ZOOM Y menus there are two dropdown menus. The first one allows you to
choose
between the different recorded signals. The second menu allows you to
switch
between Normal and Changes option of the histogram outlook.
Below the two drop-down boxes, the SMOOTH button
allows you to modify the sharpness of the histogram.
You can print the histogram using the PRINT button.
5. SCATTEROGRAM
When you press the SCATTEROGRAM button from the
DETAILS main page, you are directed toward the page where you can
review the
registered pulse variability of a patient presented in a specific way.
The number of heartbeats registered in the
different parts of the scatterogram and the specific shape of the
scatterogram
cloud are widely accepted as indicators of certain heart disorders.

The upper part of the screen presents a tachogram
with the recorded signal of the patient. In the upper right corner of
the
screen the data is displayed on a small scatterogram – changes in time
(seconds
and milivolts). An enlarged view of the scatterogram is presented on
the graph
in the middle of the screen.
Below the tachogram you will see several dropdown
menus.
The first one allows you to choose between the
channels for patient signal record.
The second menu allows you to switch between two
outlooks of the scatterogram - Normal and Changes.
The third menu gives you several options for the
view of the scatterogram – Image, 3D bars, 3D, Line, and Dot.
6. 3D TIME DISTRIBUTION
The 3D time distribution page presents the
registered frequency changes in the signal of a particular patient.

Several dropdown menus are situated in the upper
part of the screen.
The CHANNEL menu allows you to choose among the
channels through which the signals from a particular patient have been
recorded.
The TYPE menu allows you to choose the type of
analysis you are interested in.
The VIEW TYPE menu gives you several options for
the view of the graph – Image, 3D bars, 3D, Line, and Dot.
The LENGTH, STEPS, and SPACE menus allow you to
customize the outlook of the graph according to your purposes.
The PRINT button allows you to print the page.

|